ELOPREP 102
PRODUCTS
ELOPREP 102
Electrolytic Sample Preparation
ELOPREP 102, Electrolytic Polishing & Etching System
ELOPREP 102 is an automatic and programmable electrolytic polishing and etching equipment for the preparation of metallographic specimens.
ELOPREP 102
The ELOPREP 102 has advanced techniques and software with programmable coloured HMI touchscreen controls, increasing productivity, sample consistency and operator comfort. All parameters; temperature, time, current, pump speed, etc. can be monitored during the process. The speed of the amount to be pumped is also variable.
• Fully automatic electrolytic polisher/etcher
• Automatic determination of polishing and etching voltage
• Fast & effective polishing results
• Highest safety standards
• External Etching Unit
• Ability to operate two Polishing & Etching units from the same control unit
• Suitable for both normal and low-temperature electrolytic polishing






BENEFITS
Metkon products optimize your sample preparation processes with high precision, efficiency, and ease of use.


HIGH SAFETY STANDARTS
- Equipped with the highest safety standards. (Reliable electronic safety components, isolated electrolyte area, emergency stop button and many more…)
- The cooling water is automatically switched on as soon as the set temperature is reached. Thus, eliminate the overheating problem.
FULLY AUTOMATIC OPERATION
- Scanning function allows easy and exact determination of correct parameters for your sample.
- Fully automatic electrolytic polishing and etching cycle.
- Very short cycle times.
- Programmable with HMI touch screen controls.
- Most user-friendly user interface in its class.


ADVANCED FEATURES
- Two polishing & etching units can be operated from the same control unit. Thus, two different materials can be polished of etched at the same time without changing the electrolyte.
- Polishing & etching unit is suitable for both normal temperature and low temperature (sub-zero) polishing. No separate polishing & etching unit is required.
USER FRIENDLY
- Easy to change electrolytic container.
- Easily exchangeable masks allow the preparation of differently sized specimen areas. Additionally the masks allow monitoring the electrolytic flow.
- Optional external etching unit is available. It is often used when different electrolytes have to be used for polishing and etching.


FEATURES
A wide product range, programmable controls, and durable construction meet all sample preparation needs.
FULLY AUTOMATIC OPERATION CYCLE
Fully automatic electrolytic polishing and etching equipment with independent control unit. Shorter preparing time is needed for electrolytic polishing and etching process compared to traditional mechanical preparation.
AUTOMATIC DETERMINATION OF VOLTAGE
With the scanning function of ELOPREP 102, correct voltage of polishing as well as etching can be defined automatically. So, you do not need to spend long time while trying to find correct voltage manually.
7" HMI TOUCH SCREEN CONTROLS
7” coloured HMI touch screen and user-friendly software allows easy view and control. All preparation parameters can be stored in memory under a specific program number and name. These parameters are entered and stored in memory and displayed on the LCD screen as preset values. All the operator needs to do is to select the mode of operation (individual or central pressure), call up a specific program and press the “Start” key.
DUAL POLISHING & ETCHING UNITS
Additional polishing and etching unit can be connected the same control unit. Thus, two polishing & etching unit can be operated individually. This is very useful feature especially for specimens which require different electrolytes for polishing and etching.
EXCHANGEABLE ELECTROLYTE CONTAINER
The electrolyte cartridge is easily exchangeable and inserted into the polishing and etching unit. If you have different specimens, which required different electrolytes, you can use additional electrolyte containers. Thus, you do not have to change electrolyte for different types of specimen, you only need to change electrolyte container.
EXTERNAL ETCHING UNIT
Optional External etching is available incase different electrolytes have to be used for polishing and etching. ELOPREP 102 will automatically start as soon as the specimen contacts to the electrolyte in the external etching unit. The process automatically shuts down when the set etching time is reached.
TECHNICAL DATA
Technical specifications compliant with international standards ensure reliable and consistent results.
| ORDER NO | 46 02 |
| MODEL NO | ELOPREP 102 |
| Temperature limiter, C | 30 - 50 |
| Pump | Magnetic Stirrer |
| Electrolytic Container Volume, mL | 1000 ml |
| External Etching Volume, mL | 1200 ml |
| Cooling System | Integrated |
| Low Temperature Polishing | Yes |
| Mask Dimensions, cm2 | 0 - 0,5 - 1 - 2 - 5 |
| Scanning Function | Automatic |
| Control Panel | 7" HMI Touch Screen |
| Program Memory | 99 |
| Output Voltage / Current for Polishing | 0-120 V |
| Output Voltage / Current for Etching | 0-25 V |
| Output Voltage / Current for External Etching | 0-25 V |
| Power Supply | 1 x 110/120 V, |
| 1 x 230 V | |
| Dimensions of Control Unit, WxDxH, mm | 404 x 370 x 305 |
| Dimensions of Polishing Unit, WxDxH, mm | 210 x 370 x 305 |
| Weight of Control Unit, kgs | 20 |
| Weight of Polishing Unit, kgs | 5 |