close

* Los campos son obligatorios

100 gf - 10 kgf

DUROLINE LV2


Imágenes

Catálogos

Descripción

Vickers/Knoop Micro/Macro-Hardness Tester with Test & Measurement 
software Windows 10 "N-Sure" including Auto-Measurement module
Motorized spindle Z-Axis up/down movement and Auto-Focus module
closed loop load cell controlled force application
Test Loads: 100gf, 200gf, 300gf, 500gf, 1kgf, 2kgf, 3kgf, 5kgf, 10kgf
HV0,1 - HV0,2 - HV0,3 - HV0,5 - HV1 - HV2 - HV3 - HV5 - HV10
HK0,1 - HK0,2 - HK0,3 - HK0,5 - HK1 - HK3
in compliance with standard ISO 6507 and ASTM E-384.
User Interface by 22" full HD 10-point multi-touch desktop monitor,
integrated high resolution 5.0 MP, USB 3.0 CCD camera,
automatic motorized Z-axis and autofocus of indentations,
auto-measurement with zoom capability and indent image brightness, 
with automatic test sequence by motorized turret and load motor force
control by closed loop load cell system adjustable internal LED illumination, 
large sample accommodation area, emergency stop. 
Automatic voltage setting 100-240 V, 1-phase, 50/60 Hz.

Standard delivery includes: 
Hardness Tester, Desktop Monitor on solid stand, METKON N-Sure software
incl. Auto-Measurement module, Auto-Focus module with motorized Z-axis,
ISO/DaKKs Certified Vickers diamond indenter, Objective 10x, Objective 40x,
4 adjustable tester feet, Water level indicator, Indenter protection nose, 
Dust Cover, Power Cable, Monitor Interface Cable, Factory Test Certificate with
ISO/ASTM verifications, solid accessories box. 

Note: Select below the additional XY-stage, anvils, sample fixtures
and test blocks
 

Especificaciones técnicas

Metkon A.Ş.
Order No 72 06
Model LV2
Vickers HV as per ISO 6507, ASTM E384, E92 HV0,1 - HV0,2 - HV0,3 - HV0,5 - HV1 - HV2 - HV3 - HV5 - HV10
Knoop HK as per ISO 4545, ASTM E384, E92 HK0,1 - HK0,2 - HK0,3 - HK0,5 - HK1 - HK3
Hardness conversions to other scales As per ISO 18265
Test Loads (gf) 100gf, 200gf, 300gf, 500gf, 1kgf, 2kgf, 3kgf, 5kgf, 10kgf
Test Loads (N) 0,9807N - 1,961N - 2,942N - 4,904N - 9,807N - 19,631N - 29,420N - 49,033N - 98,067N
Test Load Accuracy 10gf - 200gf: +/- 1,5% and > 200gf: +/- 1,0%

As per ISO standard (and ASTM E-384, JIS B7725, JIS B7734)
Test Load Dwell Time from 5 - 99 sec with 1 sec increments

As per ISO standard (and ASTM E-384, JIS B7725, JIS B7734)
Test Load Application Speed 10gf - 200gf: < 0.070 mm/s and > 200gf: < 0.200 mm/s

As per ISO standard (and ASTM E-384, JIS B7725, JIS B7734)
Load Force Application Motorized force application with closed loop load cell control, Automatic load, dwell, unload
Load Selection By METKON N-Sure test settings
Turret Configuration Motorized 3-mount turret: 1 indenter, 2 objectives Position Auto-indication
Indenter Including 1 Vickers Diamond Indenter (ISO/DaKKs certified, Made in Germany)
Objectives Standard objectives 10X, 40X, optional 5X, 20X (Made in Germany)

Image capture by integrated CCD-camera (no eyepiece)
Sample Image Capture By Integrated CCD Camera, 5.0 MP, USB 3.0 (Made in Germany)
Indent Measurement Resolution 0,00002 mm (0,02 μm)
Illumination Source Built-in LED Light Source
Automatic Brightness Control Standard for highest contrast and sharpnes
Z-axis (Spindle Vertical Movement) Motorized
Auto-Focus AF Standard
Multiple Test & Measurements)
Multiple Test & Measurements)
Not Available
Travel Distance Not Available
Controller Built-in Windows operated mini-PC,

communicates the hardness tester electronics by CANBUS Protocol
Interface Network Interface network USB (x4), Displayport (x2), LAN (x1) and Wireless LAN
Auxilliary Optional Keyboard, Mouse (wireless)
Monitor External 22” Full HD Capacitive 10-point Multi-Touch Desktop Monitor, IPS Panel,

Antistatic Shield, Tiltable, Integrated Power Adaptor
Operating System Windows 10
User Interface Software METKON N-Sure
Test Settings Scale, Load Dwell Time , Start, Turret positioning, Hardness Conversion,
Illumination, Screen preference settings, Alerts for errors
Measurement Settings Surface Image capture, Indentation capture, Manual measurement and Auto-measurement, Single indents, Manual pattern, Preset pattern, CHD, EHT, NHT, GO/NG judgement, Statistics, Conversion, Cilindrical correction, Language, Database, Test Reports with image analysis data, Data export, User management, Service and Calibration Settings
Operational Environmental Conditions "Ambient Operating Temperature Range: 23°C +/- 5°C
Ambient Humidity Range: RH 40% to 70% relative humidity, non-condensing"
Dimensions, WxDxH 240x560x625 mm
Specimen Accommodation Vertical 185 mm, Horizontal (throat depth) 160mm
Weight 65 kgs
Mains 100-240 V, 1-phase, 50/60 Hz, autosetting

Accesorios

Operational Accessories for Vickers/Knoop Hardness Testing
  Anvils and XY-Stages Hardness Testing
GR 2021 Flat anvil diameter 80mm
GR 2022 Flat Anvil with V-groove, diameter 80mm
GR 2023 Manual XY-stage 100x100mm, travel 25x25mm, 
  with two analogue micrometers
GR 2024 Manual XY-stage 120x120mm, travel 25x25mm, 
  with one digital Slyvac micrometer incl. cable and one analogue micrometer
  (To be ordered simultaneously together with the machine order)
Object Lenses for Vickers/Knoop Hardness Testing
GR 2040 Optical Kit for 3rd Objective Mount
(To be ordered simultaneously with the machine order)
GR 2041 Object lens 5x
GR 2042 Object lens 10x
GR 2043 Object lens 20x
GR 2044 Object lens 40x
Indenters for Vickers/Knoop Hardness Testing
GR 2047 ISO/ASTM Certificated Vickers diamond indenter
GR 2048 ISO/ASTM Certificated Knoop diamond indenter
Specimen Holders for Vickers/Knoop Hardness Testing
GR 2025 Precision vise (opening 43mm)
GR 2026 Thin specimen holder
GR 2027 Fine specimen holder (Horizontal type)
GR 2028 Fine specimen holder (Vertical type)
GR 2031 Specimen holder for Ø25 mm specimens
GR 2032 Specimen holder for Ø30 mm specimens
GR 2033 Specimen holder for Ø40 mm specimens
GR 2034 Specimen holder for Ø50 mm specimens
GR 2035 Multiple specimen holder for 6xØ25 mm specimens
GR 2036 Multiple specimen holder for 6xØ30 mm specimens
GR 2037 Multiple specimen holder for 6xØ40 mm specimens
Verification Tools for Vickers/Knoop Hardness Testing
GR 2061 ISO Dakks Germany Certified standard block 200HV0.3 (30x30mm)
GR 2062 ISO Dakks Germany Certified standard block 450HV0.3 (30x30mm)
GR 2063 ISO Dakks Germany Certified standard block 700HV0.3 (30x30mm)
GR 2064 ISO Dakks Germany Certified standard block 200HV1 (30x30mm)
GR 2065 ISO Dakks Germany Certified standard block 450HV1 (30x30mm)
GR 2066 ISO Dakks Germany Certified standard block 700HV1 (30x30mm)
GR 2067 ISO Dakks Germany Certified standard block 200HV5 (60x60x6mm)
GR 2068 ISO Dakks Germany Certified standard block 450HV5 (60x60mm)
GR 2069 ISO Dakks Germany Certified standard block 700HV5 (60x60mm)
GR 2071 ISO Certificated calibration scale glass.
*Other standard test blocks are on request
Software Modules for Vickers/Knoop Hardness Testing
GR 2081 Software Module for CDH Testing (EHT)
  (Digital XY-Stage (GR2024) or Motorized stage is required)
  (To be ordered simultaneously with the machine order)

FACEBOOK TWITTER YOUTUBE LINKEDIN
Metkon